Fluke 28 II EX

Note : Harga dapat berubah sewaktu-waktuAuthorized Distributor

Now there’s one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zone 1 and 2 and IIIC (dust), Zone 21 and 22. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28 II Ex is also waterproof, dust-proof and drop-proof. You’ll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance

ntrinsic safety plus regulatory approvals

The 28 II Ex carries Ex certifications from the world’s
leading certification bodies.

28 II Ex I.S. Certifications

  • IECEx Ex ia IIC T4 Gb, Ex ia IIIC T130 °C Db, I M1 Ex ia I Ma

28 II Ex safety and regulatory compliance

  • ISA-82.02.01
  • CAN/CSA-C22.2 No. 61010-1-04 /UL61010-1:2004, and TUV 61010-1:2001
  • CE

Extreme ruggedness

The Fluke 28 II Ex is the most rugged IS DMM you can buy.

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 feet or 3 meters (with holster)
  • Dustproof per IEC60529 IP6x
  • Waterproof per IEC60529 IPx7
  • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001
    • Measurement Category III, 1000V, Pollution Degree 2
    • Measurement Category IV, 600V, Pollution Degree 2

Reversible holster for added protection of the display when not in use

Basic Accuracy Specifications
Accuracy specifications are show as +/- (% of reading + number of digits)
DC voltage
• Range 0.1 mV to 1000 V
• Accuracy ±0.05 % + 1
AC voltage
• Range: 0.1 mV to 1000 V
• Accuracy: ±0.7 % +4
DC current
• Range: 0.1 μA to 10 A
• Accuracy: ±0.2 % + 4
AC current
• Range: 0.1 μA to 10 A
• Accuracy: ±1.0 % + 2
Resistance
• Range: Range: 0.1 Ω to 50 MΩ
• Accuracy ±(0.2 % + 1)
Conductance
• Range: 60.00 nS
• Accuracy: ± (1.0 % + 10)
Diode Test
• Range: 2.0 V
• Accuracy: ± (2.0 % + 1)
Duty Cycle
• Range: 0.0 % to 99.9 %
• Accuracy: Within ±(0.2 % per kHz + 0.1 %) for rise times <1 µs
Display counts
• 6000 counts/19,999 counts in high-resolution mode
Capacitance
• Range: 10 nF to 9999 μF
• Accuracy: ± (1.0 % + 2)
Frequency
• Range: 0.5 Hz to 199.99 kHz
• Accuracy: ± (0.005 % + 1)
Temperature
• Range: -200 °C to +1090 °C (-328 °F to +1994 °F)
• Accuracy: ± (1.0 % + 10) °C [± (1.0 % + 10) °F]
Peak Capture
• Record transients up to 250 us
Min/Max/Avg Recording
• Display signals up to approximately 100 ms
Safety Specifications
Safety certifications:
ATEX
• II 2 G Ex ia IIC T4 Gb
• II 2 D Ex ia IIIC T130 °C Db
• I M1 Ex ia I Ma
NEC-500
• Class I, Div 1, Groups A-D, 130 °C
IEXEx
• Ex ia IIC T4 Gb
• Ex ia IIIC T130 °C Db
• Ex ia I Ma
GOST R Ex (Pending)
• Overvoltage protection: Measurement Category III, 1000V, Pollution Degree 2
• Measurement Category IV, 600V, Pollution Degree 2
• IP rating: IP67